×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

SHAPE MEASUREMENT OF SYNCHROTRON RADIATION WITH HIGH TIME RESOLUTION

Get Citation
CAO Zhong, LIU Wei-Ren, WANG Li-Lie, XIE Shi-Liang, JIANG Li-Ping, DING Mei-Song, ZHAO Ji-Lai, REN You-Lai, SHAN Bing, ZHAO Zheng and CUI Ming-Qi. SHAPE MEASUREMENT OF SYNCHROTRON RADIATION WITH HIGH TIME RESOLUTION[J]. Chinese Physics C, 1990, 14(8): 677-683.
CAO Zhong, LIU Wei-Ren, WANG Li-Lie, XIE Shi-Liang, JIANG Li-Ping, DING Mei-Song, ZHAO Ji-Lai, REN You-Lai, SHAN Bing, ZHAO Zheng and CUI Ming-Qi. SHAPE MEASUREMENT OF SYNCHROTRON RADIATION WITH HIGH TIME RESOLUTION[J]. Chinese Physics C, 1990, 14(8): 677-683. shu
Milestone
Received: 1900-01-01
Revised: 1900-01-01
Article Metric

Article Views(2581)
PDF Downloads(462)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

SHAPE MEASUREMENT OF SYNCHROTRON RADIATION WITH HIGH TIME RESOLUTION

    Corresponding author: CAO Zhong,
  • China Institute of Atomic Energy,Beijing1 Xian Institute of Optics and Precision Mechanics2 Institute of High Energy Physics,Academia Sinica,Beijing

Abstract: By using BWS-5k II streak camera made in China,we have measured the time structure of Synchrotron Radiation (SR) from the relatrivistic electron and positron beam bunches of Beijing Electron Positron Collider (BEPC).The dependence of SR width to the intensity of beam current and the voltage of RF source was also measured.The main data taken with 30ps time resolution in the experiment are as follows: The length of VR at Ee=1.549GeV is changed from 220ps to 670ps when the average beam current from 2mA to 30mA,the variation range of CR length at 20mA beam current is 500—700ps with RF source voltage varying between 250kV and 500kV.The time calibration uncertainty of the experiment is ±15%.The trigger jitter is less than ±200ps.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return