Development of Low Pressure Position Sensitive Multiwire Proportional Chamber

Get Citation
ZHANG Bao-Guo, WEN Wan-Xin, WEI Zhi-Yong, ZHANG Jin-Xia, FENG Ying, TAN Ji-Lian, JIN Gen-Ming, XIAO Zhi-Gang, WANG Hong-Wei, WU He-Yu, LI Zu-Yu, WANG Su-Fang and HU Rong-J. Development of Low Pressure Position Sensitive Multiwire Proportional Chamber[J]. Chinese Physics C, 2003, 27(11): 1023-1026.
ZHANG Bao-Guo, WEN Wan-Xin, WEI Zhi-Yong, ZHANG Jin-Xia, FENG Ying, TAN Ji-Lian, JIN Gen-Ming, XIAO Zhi-Gang, WANG Hong-Wei, WU He-Yu, LI Zu-Yu, WANG Su-Fang and HU Rong-J. Development of Low Pressure Position Sensitive Multiwire Proportional Chamber[J]. Chinese Physics C, 2003, 27(11): 1023-1026. shu
Milestone
Received: 2003-04-17
Revised: 1900-01-01
Article Metric

Article Views(3769)
PDF Downloads(593)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Development of Low Pressure Position Sensitive Multiwire Proportional Chamber

    Corresponding author: ZHANG Bao-Guo,
  • School of Radiation Medicine and Public Health, Suzhou University, Suzhou 215007, China2 Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China

Abstract: A low pressure two dimensional position sensitive multiwire proportional chamber (LPMWPC) has been developed for measurements of low Z charged particles from the nuclear reaction induced by radioactive ion beam. The detector has a 50mm×50mm sensitive area and consists of three grids (X-position cathode Y-position) . The position is determined through delay line readout mode. The detector has good beam transparency and is also adequate to be used in vacuum . The LPMWPC has been tested at a pressure of 800Pa of n-heptane and a bias Voltage of 720V. The test results indicate that the position resolution of the chamber is Δx = Δy = 1mm and detection efficiency is larger than 80% for the low Z particle at intermediate energies. This kind of chamber has be used to determine the direction of the incident particle.