×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Refraction Angle and Edge Visibility in X-Ray Diffraction Enhanced Imaging

  • Diffraction-enhanced X-ray imaging could extract accurately the refraction angles of the sample, which is very important to increase the image contrast of low Z samples. In this paper, the DEI experiments with X-rays of different energies were performed both on wedge-shaped and rounded model samples. Refraction angles of the two samples were all obtained accurately, and the results agreed well with the calculations. Quantitative analyses based on Edge Visibility were performed for the wedge-shaped model sample. The results revealed that the calculated positions for the Best Edge Visibility of the slope with fixed refraction angle were calculable in good agreement with the experimental results. A quantitative research on the Edge Visibility of real tissues sample was carried out and the optimal condition for best contrast of DEI images were discussed.
  • 加载中
  • [1] . Fitzgerald R. Physics Today Online, 2000 July2. Bravin A. J. Phys. D: Appl. Phys., 2003, 36: A24-A293. JIANG Xiao-Ming et al. HEP NP, 2004, 28: 1282(inChinese) (姜晓明等.高能物理与核物理,2004, 28: 1282)4. David C et al. Appl. Phys. Lett., 2002, 81: 32875. Momose A et al. J. Synchrotron. Rad., 2002, 9: 1366. Snigirev A et al. Rev. Sci. Instrum., 1995, 66: 54867. Chapman D et al. Phys. Med. Biol., 1997, 42: 20158. ZHONG Z et al. Nucl. Instrum. Methods, 2000, A450: 5569. Wernick M N et al. Phys. Med. Biol., 2003, 48: 387510. Wagner A et al. Phys. Med. Biol., 2006, 51: 131311. Connor D M et al. Phys. Med. Biol., 2006, 51: 3283-330012. HUANG Zhi-Feng et al. Phys. Med. Biol., 2006, 51: 303113. Keyrilainen J et al. Nucl. Instrum. Methods, 2002, A488:41914. Wernick M N et al. Phys. Med. Biol., 2003, 48: 3875-389515. HUANG Zhi-Feng. Research on Extraction Methods ofPhase Information and CT Reconstruction Algorithms inDi raction Enhanced Imaging. Tsinghua University, 2006(inChinese) (黄志峰.衍射增强成像的相位信息提取方法和CTS建算法训究.清华大学博士论文,2006)16. Born M, Wolf E. Principles of Optics. 6th edn. Cambridge:Cambridge University Press, 198017. Pagot E et al. Phys. Med. Biol., 2005, 50: 709-72418. Kiss M Z et al. Phys. Med. Biol., 2003, 48: 32519. YUAN Qing-Xi et al. HEP NP, 2005, 29: 1023(inChinese) (袁清习等.高能物理与核物理,2005, 29: 1023) 20. Bravin A et al. Proc. SPIE, 2002, 4682: 167-173
  • 加载中

Get Citation
CHEN Yu, JIA Quan-Jie, LI Gang, WANG Yu-Zhu, XUE Xian-Ying, JIANG Xiao-Ming, CHEN Zhi-Hua, PAN Lin and LI Hong-Yan. Refraction Angle and Edge Visibility in X-Ray Diffraction Enhanced Imaging[J]. Chinese Physics C, 2007, 31(10): 982-989.
CHEN Yu, JIA Quan-Jie, LI Gang, WANG Yu-Zhu, XUE Xian-Ying, JIANG Xiao-Ming, CHEN Zhi-Hua, PAN Lin and LI Hong-Yan. Refraction Angle and Edge Visibility in X-Ray Diffraction Enhanced Imaging[J]. Chinese Physics C, 2007, 31(10): 982-989. shu
Milestone
Received: 2007-01-04
Revised: 2007-03-26
Article Metric

Article Views(2820)
PDF Downloads(538)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Refraction Angle and Edge Visibility in X-Ray Diffraction Enhanced Imaging

    Corresponding author: JIANG Xiao-Ming,
  • Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China2 China-Japan Friendship Hospital, China-Japan Friendship Institute of Clinical Medical Science,Department of Biochemistry and Molecular Biology, Beijing 100029, China

Abstract: Diffraction-enhanced X-ray imaging could extract accurately the refraction angles of the sample, which is very important to increase the image contrast of low Z samples. In this paper, the DEI experiments with X-rays of different energies were performed both on wedge-shaped and rounded model samples. Refraction angles of the two samples were all obtained accurately, and the results agreed well with the calculations. Quantitative analyses based on Edge Visibility were performed for the wedge-shaped model sample. The results revealed that the calculated positions for the Best Edge Visibility of the slope with fixed refraction angle were calculable in good agreement with the experimental results. A quantitative research on the Edge Visibility of real tissues sample was carried out and the optimal condition for best contrast of DEI images were discussed.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return