×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Study on the Performance of the YBJ-ARGO RPC

  • YBJ-ARGO experiment is designed to detect small size air showers at an energy threshold of~100GeV using a full coverage RPC array. High detector efficiency, good time resolution (~1ns) and low strip multiplicity (~1.2) are needed to meet the experiment requirements. Performance of RPC, including the above mentioned detector parameters together with the RPC current, is studied at high altitude (4300m a.s.l.) with a normal RPC gas mixture, under which high strip and hit multiplicity effect is observed due to the float of the CHAMBER mass reference which creates concomitant strip multiplicity when a large streamer develops in the CHAMBER. By adding SF6 component into the gas mixture to limit the streamer development together with adjusting the pull-down threshold of the signal-receiving system, the mass-reference-float effect is effectively eliminated, thus achieving lower strip multiplicity and lower working current under the same working high voltage.
  • 加载中
  • [1] . Abbressics M et al . Astroparticle Physics with ARGO Proposal , 19962. LU Hong et al . HEP NP , 1999 , 23 : 417 —424 (in Chinese)(卢红等. 高能物理与核物理,1999 ,23 : 417 —424)3. HE Hui-Hai et al . HEP NP , 2001 , 25(1) : 79 —85 (in Chinese)(何会海等. 高能物理与核物理,2001 ,25(1) : 79 —85)4. QU Ruo-Fei et al . HEP NP , 2001 , 25(5) : 371 —376 (in Chinese)(瞿若飞等. 高能物理与核物理,2001 ,25 (5) : 371 —376)5. Santonico R et al . Nucl . Instrum. Methods , 1981 , A187 :3776. Cardarelli R et al . Nucl . Instrum. Methods , 1988 , A263 :207. Camarri R et al . Nucl . Instrum. Methods , 1998 , A414 :3178. Santonico R et al . Nucl . Instrum. Methods , 2002 , A493 :137
  • 加载中

Get Citation
HE Hui-Hai, LIU Kun, LU Hong, SHEN Pei-Ruo, TAN You-Heng, WU Chao-Yong, YANG Qun-Yu, ZHANG Hui-Min and ZHANG Yong. Study on the Performance of the YBJ-ARGO RPC[J]. Chinese Physics C, 2004, 28(4): 422-425.
HE Hui-Hai, LIU Kun, LU Hong, SHEN Pei-Ruo, TAN You-Heng, WU Chao-Yong, YANG Qun-Yu, ZHANG Hui-Min and ZHANG Yong. Study on the Performance of the YBJ-ARGO RPC[J]. Chinese Physics C, 2004, 28(4): 422-425. shu
Milestone
Received: 2003-07-23
Revised: 1900-01-01
Article Metric

Article Views(3585)
PDF Downloads(588)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Study on the Performance of the YBJ-ARGO RPC

    Corresponding author: HE Hui-Hai,
  • Institute of High Energy Physics,CAS,Beijing 100039,China2 Department of Physics,Yunnan University,Kunming 650091,China

Abstract: YBJ-ARGO experiment is designed to detect small size air showers at an energy threshold of~100GeV using a full coverage RPC array. High detector efficiency, good time resolution (~1ns) and low strip multiplicity (~1.2) are needed to meet the experiment requirements. Performance of RPC, including the above mentioned detector parameters together with the RPC current, is studied at high altitude (4300m a.s.l.) with a normal RPC gas mixture, under which high strip and hit multiplicity effect is observed due to the float of the CHAMBER mass reference which creates concomitant strip multiplicity when a large streamer develops in the CHAMBER. By adding SF6 component into the gas mixture to limit the streamer development together with adjusting the pull-down threshold of the signal-receiving system, the mass-reference-float effect is effectively eliminated, thus achieving lower strip multiplicity and lower working current under the same working high voltage.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return