×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Preparation of 182Hf AMS Standard Sample and Test on HI-13 Tandem AMS

Get Citation
YIN Xin-Yi, HE Ming, DONG Ke-Jun, QIU Jiu-Zi, WU Shao-Yong, ZHANG Jin-Song, ZHANG Chun-Hua, ZHENG Yun, GUAN Yong-Jing and JIANG Shan. Preparation of 182Hf AMS Standard Sample and Test on HI-13 Tandem AMS[J]. Chinese Physics C, 2007, 31(10): 978-981.
YIN Xin-Yi, HE Ming, DONG Ke-Jun, QIU Jiu-Zi, WU Shao-Yong, ZHANG Jin-Song, ZHANG Chun-Hua, ZHENG Yun, GUAN Yong-Jing and JIANG Shan. Preparation of 182Hf AMS Standard Sample and Test on HI-13 Tandem AMS[J]. Chinese Physics C, 2007, 31(10): 978-981. shu
Milestone
Received: 2006-11-28
Revised: 2007-03-19
Article Metric

Article Views(3545)
PDF Downloads(582)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Preparation of 182Hf AMS Standard Sample and Test on HI-13 Tandem AMS

    Corresponding author: YIN Xin-Yi,
  • Department of Nuclear Physics, China Institute of Atomic Energy, Beijing 102413, China2 Nuclear Power Institute of China, Sichuan, Jiajiang 610005, China

Abstract: The preparation and accelerator mass spectrometry (AMS) measurements of a series of 182Hf AMS calibration standards are described in this paper. The preparation consists of five processes, the synthesis of the initial 182Hf/180Hf standard sample by double neutron capture reaction of 180Hf, the accurate measurement of this standard for isotopic ratio with thermal ionization mass spectrometry (TIMS), the chemical separation of isobaric interference 182W, the sequential dilution of the initial standard, and the preparation of HfF4. The value of 182Hf/180Hf in the initial 182Hf/180Hf standard was obtained with TIMS to be (1.63±0.01)×10-6. Chemical separation and purification procedures were developed and applied in the preparation of all 182Hf/180Hf standards for the removal of major isobaric interference nuclide 182W. As a result, three 182Hf AMS standards with 182Hf/180Hf ratios of (1.63±0.01)×10-6, (3.22±0.26)×10-8, (3.45±0.32)×10-10 were obtained. AMS measurements of these standard samples were performed and good linearity was obtained in a plot of AMS results vs nominal values for 182Hf/180Hf ranging from 1.63×10-6 to 3.45×10-10.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return