×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Medium-Type Pulsed Fast-Neutron Detector

Get Citation
OUYANG Xiao-Ping, LI Zhen-Fu, HUO Yu-Kun, ZHANG Zhong-Bing, SHEN Han-Liang and ZHANG Qian-Mei. Medium-Type Pulsed Fast-Neutron Detector[J]. Chinese Physics C, 2001, 25(11): 1100-1105.
OUYANG Xiao-Ping, LI Zhen-Fu, HUO Yu-Kun, ZHANG Zhong-Bing, SHEN Han-Liang and ZHANG Qian-Mei. Medium-Type Pulsed Fast-Neutron Detector[J]. Chinese Physics C, 2001, 25(11): 1100-1105. shu
Milestone
Received: 2000-11-14
Revised: 1900-01-01
Article Metric

Article Views(3368)
PDF Downloads(590)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Medium-Type Pulsed Fast-Neutron Detector

    Corresponding author: OUYANG Xiao-Ping,
  • Institute of Modern Physics,Fudan University,Shanghai 200433,China2 Northwestern Institute of Nuclear Technology,Xi'an 710024,China3 Institute of Acoustic Engineering,Northwestern Polytechnic University,Xi'an 710054,China4 Institute of Modern Physics,The Chinese Academy of Sciences,Lanzhou 730000,China

Abstract: In this paper a newly developed medium-type pulsed fast neutron detector is proposed. The detector consists of front insulator,n-p converter,absorber,collector and rear insulator. The detection principle is based on the output signal from both recoil-protons of the n-p converter and secondary electrons induced by the recoil protons passing the interface between the absorber and the collector. Because of its detection of fast neutrons in the medium,unlike many trandifional fast neutron detectors which work in the vacuum environment,this detector has obvious advantages. It does not need vacuum environment and high voltage power supply. This makes it to be used easily. By choosing teflon as the absorber and by choosing graphite as the charge collector,the contribution of the secondary electrons to the output signal can be determined experimentally.

    HTML

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return