×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Time-Resolved Emittance Measurement of Intense Pulse Beams Using the Modified Three Gradient Method

  • The three gradient method is a conventional means for beam emittance measurement. In intense electron beam accelerators,since the space charge effect is remarkable, the conventional three gradient method in not available.A MTGM(abbreviation for the Modified Three Gradient Method)is an improvement of the conventional three gradient method, the space charge effect is included in this method. In this paper, the basic theory of MTGM is stated, the principle of applying the MTGM method to beam diagnostics is described. Experiments are carried out on two electron beams of 3.5MeV, 2.6kA, 100ns and 18MeV,2.6kA 100ns separately, which scheme is presented. Results of these experiments are presented together with the error analysis. The results show that the MTGM method is an effective way of emittance measurement for intense pulse electron beam.
  • 加载中
  • [1] . HUI Z X, YANG Z H. Free Electron Laser. National Defence Industry Press , 1995. 12. (in Chinese)(惠钟锡,杨震华. 自由电子激光. 国防工业出版社,1995. 12)2. WANG S H , YE Q , CAO J S et al . HEP NP , 2002 , 26 : 1184 —1188 (in Chinese)(王书鸿,叶强,曹建社等. 高能物理与核物理,2002 ,26 :1184 —1188)3. Bardy J , Bonnafond C et al . Status of AIRIX Alignment and High Current Electron Beam Diagnostics. Proceeding of EPAC964. Richard B R , Ekdahl C et al . Beam Emittance Diagnostic for theDARHT Second Axis Injector. Proceeding of Pulsed Power Conference ,20015. Marghitu S , Oproiu C et al . Pulsed Electron Source Characterization with the Modified Three Gradient Method. Proceeding of International Conference on Accelerator and Large Experimental Physics Control Systems , 20016. DAI Z Y. Research of the Increase Mechanism and Decrease Means for Beam Emittance of the Linear Induction Accelerator. Doctor Dissertation. Beijing : China Academy of Science , 2004 (in Chinese)(代志勇. 直线感应加速器束流发射度增长与抑制研究. 中国科学院研究生院博士学位论文,2004)7. GUAN Z, CHEN J L. Numerical Computational Methods. Tsinghua University Press , 1990. 8 (in Chinese)(关治,陈景良. 数值计算方法. 清华大学出版社,1990. 8)
  • 加载中

Get Citation
YANG Guo-Jun, ZHANG Zhuo, CHEN Si-Fu, LIU Cheng-Jun and LIN Yu-Zheng. Time-Resolved Emittance Measurement of Intense Pulse Beams Using the Modified Three Gradient Method[J]. Chinese Physics C, 2005, 29(2): 191-196.
YANG Guo-Jun, ZHANG Zhuo, CHEN Si-Fu, LIU Cheng-Jun and LIN Yu-Zheng. Time-Resolved Emittance Measurement of Intense Pulse Beams Using the Modified Three Gradient Method[J]. Chinese Physics C, 2005, 29(2): 191-196. shu
Milestone
Received: 2004-06-16
Revised: 2004-07-26
Article Metric

Article Views(2795)
PDF Downloads(611)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Time-Resolved Emittance Measurement of Intense Pulse Beams Using the Modified Three Gradient Method

    Corresponding author: YANG Guo-Jun,
  • Department of Engineering Physics,Tsinghua University,Beijing 100084,China2 Institute of Fluid Physics,CAEP,Mianyang 621900,China

Abstract: The three gradient method is a conventional means for beam emittance measurement. In intense electron beam accelerators,since the space charge effect is remarkable, the conventional three gradient method in not available.A MTGM(abbreviation for the Modified Three Gradient Method)is an improvement of the conventional three gradient method, the space charge effect is included in this method. In this paper, the basic theory of MTGM is stated, the principle of applying the MTGM method to beam diagnostics is described. Experiments are carried out on two electron beams of 3.5MeV, 2.6kA, 100ns and 18MeV,2.6kA 100ns separately, which scheme is presented. Results of these experiments are presented together with the error analysis. The results show that the MTGM method is an effective way of emittance measurement for intense pulse electron beam.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return