×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Measurements of 41Ca in Biological Samples by AMS Using CaF2 Target

  • For determining numbers of 41Ca labeled biological samples, the analytical method of 41Ca/40Ca by Accelerator Mass Spectrometry (AMS) using CaF2 target was developed at the Beijing HI-13 AMS system. 41Ca in the biological samples and 41Ca standard samples were prepared to CaF2 with a more effective chemical separation and purification procedure. In the 41Ca AMS measurement, CaF3 negative ion was extracted from ion resource, 7+ charge state of particles was chosen after carbon foil stripping and accelerated at 8.5MV terminal voltage. 41Ca ions were finally recorded by an 140mbar P10 gas filled multi-anode ionization chamber detector. The results showed that 41Ca and the main isobar, 41K could be clearly identified in the two-dimensional density spectra, and the interference of 41K to 41Ca was eliminated with the very low 41K counting rate. The absolute measured values of 4 standard samples with 41Ca/40Ca in the range of 1.785×10-8—1.750×10-10 were in good linear relationship with the standard values (r2=0.997). After normalized with the 1.785×10-841Ca/40Ca standard, the measured values of S2 and S4 standard samples were in good agreement with the nominal values, however, the measured value of S3 deviated the nominal value largely. The 41Ca/40Ca of the biological blanks were estimated below 8.2×10-13.
  • 加载中
  • [1] . Johnson R R, Berkovits D, Boaretto E et al. Nucl. Instrum.Methods, 1994, B92: 483—4882. Freeman S P H T, Beck B, Bierman J M et al. Nucl. In-strum. Methods, 2000, B172: 930—9333. JIANG Shan, HE Ming, DONG Ke-Jun et al. Nucl. In-strum. Methods, 2004, B223/224: 750—7534. Fink D, Middleton R, Klein J et al. Nucl. Instrum. Meth-ods. Phys. Res., 1990, B47: 79—965. Freeman S P H T, Serfass R E, King J C et al. Nucl. In-strum. Methods. Phys. Res., 1995, B99: 557—5616. DONG Ke-Jun, HE Ming, WU Shao-Yong et al. ChinesePhys. Lett., 2004, 21(1): 51—537. YUE Dong-Fang, DONG Ke-Jun, HE Ming et al. Atom.Energy Sci. and Tech., 2004, 38(3): 271—274(in Chinese)(岳东方,董克君,何明等.原子能科学技术,2004, 38(3):271-274)8. WU Shao-Yong, JIANG Shan, DONG Ke-Jun et al. J.Chin. Mass Spectr. Soc., 2002, 23(4): 248—251(in Chinese)(武绍勇,姜山,董克君等.质谱学报,2002, 23(4): 248-251)
  • 加载中

Get Citation
LI Shi-Hong, JIANG Shan, HE Ming, GUAN Yong-Jing, DONG Ke-Jun, WU Shao-Yong, YUAN Yuan, MI Sheng-Quan, LIU Shu-Tian and YUAN Jian. Measurements of 41Ca in Biological Samples by AMS Using CaF2 Target[J]. Chinese Physics C, 2005, 29(12): 1210-1213.
LI Shi-Hong, JIANG Shan, HE Ming, GUAN Yong-Jing, DONG Ke-Jun, WU Shao-Yong, YUAN Yuan, MI Sheng-Quan, LIU Shu-Tian and YUAN Jian. Measurements of 41Ca in Biological Samples by AMS Using CaF2 Target[J]. Chinese Physics C, 2005, 29(12): 1210-1213. shu
Milestone
Received: 2005-03-04
Revised: 1900-01-01
Article Metric

Article Views(5168)
PDF Downloads(731)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Measurements of 41Ca in Biological Samples by AMS Using CaF2 Target

    Corresponding author: LI Shi-Hong,
  • Department of Nuclear Physics,Chinese Institute of Atomic Energy,Beijing 102413,China

Abstract: For determining numbers of 41Ca labeled biological samples, the analytical method of 41Ca/40Ca by Accelerator Mass Spectrometry (AMS) using CaF2 target was developed at the Beijing HI-13 AMS system. 41Ca in the biological samples and 41Ca standard samples were prepared to CaF2 with a more effective chemical separation and purification procedure. In the 41Ca AMS measurement, CaF3 negative ion was extracted from ion resource, 7+ charge state of particles was chosen after carbon foil stripping and accelerated at 8.5MV terminal voltage. 41Ca ions were finally recorded by an 140mbar P10 gas filled multi-anode ionization chamber detector. The results showed that 41Ca and the main isobar, 41K could be clearly identified in the two-dimensional density spectra, and the interference of 41K to 41Ca was eliminated with the very low 41K counting rate. The absolute measured values of 4 standard samples with 41Ca/40Ca in the range of 1.785×10-8—1.750×10-10 were in good linear relationship with the standard values (r2=0.997). After normalized with the 1.785×10-841Ca/40Ca standard, the measured values of S2 and S4 standard samples were in good agreement with the nominal values, however, the measured value of S3 deviated the nominal value largely. The 41Ca/40Ca of the biological blanks were estimated below 8.2×10-13.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return