Simulation of background reduction and Compton suppression in a low-background HPGe spectrometer at a surface laboratory

Get Citation
NIU Shun-Li, CAI Xiao, WU Zhen-Zhong, LIU Yi, XIE Yu-Guang, YU Bo-Xiang, WANG Zhi-Gang, FANG Jian, SUN Xi-Lei, SUN Li-Jun, LIU Ying-Biao, GAO Long, ZHANG Xuan, ZHAO Hang, ZHOU Li, HU Tao and Simulation of background reduction and Compton suppression in a low-background HPGe spectrometer at a surface laboratory[J]. Chinese Physics C, 2015, 39(8): 086002. doi: 10.1088/1674-1137/39/8/086002
NIU Shun-Li, CAI Xiao, WU Zhen-Zhong, LIU Yi, XIE Yu-Guang, YU Bo-Xiang, WANG Zhi-Gang, FANG Jian, SUN Xi-Lei, SUN Li-Jun, LIU Ying-Biao, GAO Long, ZHANG Xuan, ZHAO Hang, ZHOU Li, HU Tao and Simulation of background reduction and Compton suppression in a low-background HPGe spectrometer at a surface laboratory[J]. Chinese Physics C, 2015, 39(8): 086002.  doi: 10.1088/1674-1137/39/8/086002 shu
Milestone
Received: 2014-10-20
Revised: 2015-03-17
Article Metric

Article Views(1677)
PDF Downloads(231)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Simulation of background reduction and Compton suppression in a low-background HPGe spectrometer at a surface laboratory

    Corresponding author: NIU Shun-Li,
    Corresponding author: CAI Xiao,

Abstract: High-purity germanium (HPGe) detectors are well suited to analyse the radioactivity of samples. In order to reduce the environmental background for an ultra-low background HPGe spectrometer, low-activity lead and oxygen free copper are installed outside the probe to shield from gamma radiation, with an outer plastic scintillator to veto cosmic rays, and an anti-Compton detector to improve the peak-to-Compton ratio. Using Geant4 tools and taking into account a detailed description of the detector, we optimize the sizes of these detectors to reach the design requirements. A set of experimental data from an existing HPGe spectrometer was used to compare with the simulation. For the future low-background HPGe detector simulation, considering different thicknesses of BGO crystals and anti-coincidence efficiency, the simulation results show that the optimal BGO thickness is 5.5 cm, and the peak-to-Compton ratio of 40K is raised to 1000 when the anti-coincidence efficiency is 0.85. In the background simulation, 15 cm oxygen-free copper plus 10 cm lead can reduce the environmental gamma rays to 0.0024 cps/100 cm3 Ge (50 keV--2.8 MeV), which is about 10-5 of the environmental background.