×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Performance assessment of CsI(Tl) screens on varioussubstrates for X-ray imaging

Get Citation
FENG Zhao-Dong, JIANG Peng, ZHANG Hong-Kai, ZHAO Bo-Zhen, QIN Xiu-Bo, WEI Cun-Feng, LIU Yu and WEI Long. Performance assessment of CsI(Tl) screens on varioussubstrates for X-ray imaging[J]. Chinese Physics C, 2015, 39(7): 078202. doi: 10.1088/1674-1137/39/7/078202
FENG Zhao-Dong, JIANG Peng, ZHANG Hong-Kai, ZHAO Bo-Zhen, QIN Xiu-Bo, WEI Cun-Feng, LIU Yu and WEI Long. Performance assessment of CsI(Tl) screens on varioussubstrates for X-ray imaging[J]. Chinese Physics C, 2015, 39(7): 078202.  doi: 10.1088/1674-1137/39/7/078202 shu
Milestone
Received: 2014-10-20
Revised: 2015-01-30
Article Metric

Article Views(1807)
PDF Downloads(81)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Performance assessment of CsI(Tl) screens on varioussubstrates for X-ray imaging

    Corresponding author: QIN Xiu-Bo,

Abstract: Thallium-doped cesium iodide (CsI(Tl)) screens are widely used in X-ray imaging devices because of the columnar structure of the CsI(Tl) layer, but few reports focus on the optical role of the substrate in the screen system. In this paper, four substrates including fused silica (SiO2), silver-film coated SiO2, graphite (C) and fiber optic plate (FOP) are used to fabricate CsI(Tl) screens by thermal evaporation. Their imaging performance is evaluated by relative light output (RLO), modulation transfer function (MTF), normalized noise power spectrum (NNPS) and noise equivalent quanta (NEQ). The results reveal that although CsI(Tl) film on graphite plate yields images with the lowest light output, it presents relatively higher spatial resolution and better signal-to-noise characteristics. However, films on SiO2 plate obtain low MTF but high NNPS curves, whether they are coated with silver film or not. Furthermore, scintillation screens on FOP have bright images with low NNPS and high NEQ, but have the lowest MTF. By controlling the substrate optical features, CsI(Tl) films can be tailored to suit a given application.

    HTML

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return