Measurement of the half-life of 79Se with accelerator mass spectrometry

Get Citation
DOU Liang, JIANG Shan, WANG Xiao-Bo, DONG Ke-Jun, WU Shao-Yong, YANG Xu-Ran, WANG Xiao-Ming, LAN Xiao-Xi, XIA Qing-Liang and HE Ming. Measurement of the half-life of 79Se with accelerator mass spectrometry[J]. Chinese Physics C, 2014, 38(10): 106204. doi: 10.1088/1674-1137/38/10/106204
DOU Liang, JIANG Shan, WANG Xiao-Bo, DONG Ke-Jun, WU Shao-Yong, YANG Xu-Ran, WANG Xiao-Ming, LAN Xiao-Xi, XIA Qing-Liang and HE Ming. Measurement of the half-life of 79Se with accelerator mass spectrometry[J]. Chinese Physics C, 2014, 38(10): 106204.  doi: 10.1088/1674-1137/38/10/106204 shu
Milestone
Received: 2013-10-09
Revised: 1900-01-01
Article Metric

Article Views(1989)
PDF Downloads(158)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Measurement of the half-life of 79Se with accelerator mass spectrometry

    Corresponding author: HE Ming,

Abstract: The accelerator mass spectrometry (AMS) is an effective method for the determination of the half-life of long-lived radionuclides. In this paper, we report a method for measurement of the half-life of 79Se. The number of 79Se atoms was determined from measured 79Se/Se absolute ratios with the AMS system at the China Institute of Atomic Energy and the decay rate of 79Se was determined by counting the emitted β-rays with a liquid scintillation spectrometer. The major improvements of our measurements include using the high abundance of an 79Se sample which was cooled for many years to exclude the interference of short-lived nuclides, the extraction of SeO2- molecular ions, that results in a suppression of the 79Br background by as much as about five orders of magnitude. Also, an AMS measurement of the absolute ratio of 79Se/Se was developed to avoid systematic errors. The results show that 79Se/Se is (2.35±0.12)×10-7 in the reference sample and the radioactivity of 79Se is (1.24±0.05) Bq/g, so the half-life of 79Se is (2.78±0.18)×105 a.