×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

A geometric factor calculation method based on the isotropic flux assumption

Get Citation
ZHAO Xiao-Yun, WANG Huan-Yu, WU Feng, MENG Xiang-Cheng, MA Yu-Qian, LU Hong, WANG Hui, WANG Ping, LI Xin-Qiao, XU Yan-Bin, SHI Feng, JIANG Wen-Qi, AN Zhen-Hua, YU Xiao-Xia and LIU Han-Yi. A geometric factor calculation method based on the isotropic flux assumption[J]. Chinese Physics C, 2013, 37(12): 126201. doi: 10.1088/1674-1137/37/12/126201
ZHAO Xiao-Yun, WANG Huan-Yu, WU Feng, MENG Xiang-Cheng, MA Yu-Qian, LU Hong, WANG Hui, WANG Ping, LI Xin-Qiao, XU Yan-Bin, SHI Feng, JIANG Wen-Qi, AN Zhen-Hua, YU Xiao-Xia and LIU Han-Yi. A geometric factor calculation method based on the isotropic flux assumption[J]. Chinese Physics C, 2013, 37(12): 126201.  doi: 10.1088/1674-1137/37/12/126201 shu
Milestone
Received: 2013-02-19
Revised: 2013-04-02
Article Metric

Article Views(2141)
PDF Downloads(291)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

A geometric factor calculation method based on the isotropic flux assumption

    Corresponding author: ZHAO Xiao-Yun,
    Corresponding author: WANG Huan-Yu,

Abstract: One of the instruments onboard the China Seismic Electromagnetic Satellite (CSES) is the Low Energy Particle Detector (LEPD). The primary objective of LEPD is to provide measurements of the fluxes, energy spectra and pitch angles of 100 keV to 10 MeV electrons and protons from 2 to 50 MeV in the Earth's magnetosphere. The geometric factor is one of the principle parameters of a detector, which converts the physical quantity-count rate to the particle quantity-flux. In this paper, we calculated the geometric factor of LEPD via computer modeling of an isotropic radiation environment. It was first demonstrated that the radiation intensity related should obey a cosine-law, then a general sampling method of generating this distribution via GPS of GEANT4 was explained. Furthermore, combined with flux normalization, a comparison of the geometric factor calculation of a set of 2-layer detectors with different shapes (cylinder, truncated cone and rectangle) was performed. Results show a generally good agreement between simulation and analytical calculations for the cylinder and truncated cone detectors, and the result of the rectangular one, for which there is no accurate analytical formula, is consistent with the previous simulated results by others. As a practical instance of the 2-layer rectangle detector, the geometric factor of LEPD is 10.336±0.036 m cm2·sr for 10 MeV proton and 8.211±0.032 m cm2·sr for 8 MeV electron.

    HTML

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return