×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

First neutron spectrometry measurement at the HL-2A Tokamak

Get Citation
YUAN Xi, ZHANG Xing, XIE Xu-Fei, CHEN Zhong-Jing, PENG Xing-Yu, FAN Tie-Shuan, CHEN Jin-Xiang, LI Xiang-Qing, YUAN Guo-Liang, YANG Qing-Wei and YANG Jin-Wei. First neutron spectrometry measurement at the HL-2A Tokamak[J]. Chinese Physics C, 2013, 37(12): 126001. doi: 10.1088/1674-1137/37/12/126001
YUAN Xi, ZHANG Xing, XIE Xu-Fei, CHEN Zhong-Jing, PENG Xing-Yu, FAN Tie-Shuan, CHEN Jin-Xiang, LI Xiang-Qing, YUAN Guo-Liang, YANG Qing-Wei and YANG Jin-Wei. First neutron spectrometry measurement at the HL-2A Tokamak[J]. Chinese Physics C, 2013, 37(12): 126001.  doi: 10.1088/1674-1137/37/12/126001 shu
Milestone
Received: 2013-04-11
Revised: 1900-01-01
Article Metric

Article Views(1892)
PDF Downloads(307)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

First neutron spectrometry measurement at the HL-2A Tokamak

    Corresponding author: FAN Tie-Shuan,

Abstract: A compact neutron spectrometer based on the liquid scintillator is presented for neutron energy spectrum measurements at the HL-2A Tokamak. The spectrometer was well characterized and a fast digital pulse shape discrimination software was developed using the charge comparison method. A digitizer data acquisition system with a maximum frequency of 1 MHz can work under an environment with a high count rate at HL-2A Tokamak. Specific radiation and magnetic shielding for the spectrometer were designed for the neutron spectrum measurement at the HL-2A Tokamak. For pulse height spectrum analysis, dedicated numerical simulation utilizing NUBEAM combined with GENESIS was performed to obtain the neutron energy spectrum. Subsequently, the transportation process from the plasma to the detector was evaluated with Monte Carlo calculations. The distorted neutron energy spectrum was folded with the response matrix of the liquid scintillation spectrometer, and good consistency was found between the simulated and measured pulse height spectra. This neutron spectrometer based on a digital acquisition system could be well adopted for the investigation of the auxiliary heating behavior and the fast-ion related phenomenon on different tokamak devices.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return