Optimization of the in-line X-ray phase-contrast imaging setup considering edge-contrast enhancement and spatial resolution

Get Citation
JIA Quan-Jie, CHEN Yu, LI Gang and JIANG Xiao-Ming. Optimization of the in-line X-ray phase-contrast imaging setup considering edge-contrast enhancement and spatial resolution[J]. Chinese Physics C, 2012, 36(3): 267-274. doi: 10.1088/1674-1137/36/3/014
JIA Quan-Jie, CHEN Yu, LI Gang and JIANG Xiao-Ming. Optimization of the in-line X-ray phase-contrast imaging setup considering edge-contrast enhancement and spatial resolution[J]. Chinese Physics C, 2012, 36(3): 267-274.  doi: 10.1088/1674-1137/36/3/014 shu
Milestone
Received: 2011-05-16
Revised: 2011-07-29
Article Metric

Article Views(2436)
PDF Downloads(377)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Optimization of the in-line X-ray phase-contrast imaging setup considering edge-contrast enhancement and spatial resolution

    Corresponding author: JIANG Xiao-Ming,

Abstract: Employing the approximation theory based on refraction and the definition of the total point-spread-function of the imaging system, the variation in the edge contrast of simple model samples is discussed with different source-to-sample and sample-to-detector distances, which actually means different spatial resolutions of the imaging system. The experiments were carried out with the Beamline 4W1A imaging setup at the Beijing Synchrotron Radiation Facility for simple model and insect samples. The results show that to obtain clear phase-contrast images of biologic tissues for the X-ray in-line imaging setup, with determined parameters such as the size of the X-ray source, the pixel size of the detector and the fixed source-to-sample distance, there is a range of optimized sample-to-detector distances. The analysis method discussed in this article can be helpful in optimizing the setup of X-ray in-line phase-contrast imaging.