×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Simulation and experimental study of the solid pulse forming lines for dielectric wall accelerator

Get Citation
ZHAO Quan-Tang, YUAN Ping, ZHANG Zi-Min, CAO Shu-Chun, SHEN Xiao-Kang, LIU Ming, JING Yi and ZHAO Hong-Wei. Simulation and experimental study of the solid pulse forming lines for dielectric wall accelerator[J]. Chinese Physics C, 2011, 35(12): 1148-1151. doi: 10.1088/1674-1137/35/12/013
ZHAO Quan-Tang, YUAN Ping, ZHANG Zi-Min, CAO Shu-Chun, SHEN Xiao-Kang, LIU Ming, JING Yi and ZHAO Hong-Wei. Simulation and experimental study of the solid pulse forming lines for dielectric wall accelerator[J]. Chinese Physics C, 2011, 35(12): 1148-1151.  doi: 10.1088/1674-1137/35/12/013 shu
Milestone
Received: 2011-03-25
Revised: 2011-05-03
Article Metric

Article Views(2173)
PDF Downloads(434)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Simulation and experimental study of the solid pulse forming lines for dielectric wall accelerator

    Corresponding author: ZHAO Quan-Tang,
    Corresponding author: YUAN Ping,

Abstract: Two types of pulse forming lines for dielectric wall accelerator (DWA) were investigated preliminarily. By simulation with CST Microwave Studio, the results indicate the pulse forming process, which can help to understand the voltage wave transmission process and optimize the line parameters. Furthermore, the principle of the pulse forming process was proved by experiments and some excellent pulse waveforms were obtained. During the experiments, the Blumlein line and zero integral pulse (ZIP) forming line, constructed with aluminum foil, poly plate and air gap self-closing switch, were tested. The full width at half maximum (FWHM) of the waveform is 16 nanoseconds (BL) and 17 nanoseconds (ZIP line),and the formed pulse voltage amplitude is 5 kV (BL) and +2.2 kV/ - 1.6 kV (ZIP line). The experiments result coincides well with the simulation.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return