Tuning of RF amplitude and phase for the drift tube linac in J-PARC

Get Citation
SHEN Guo-Bao and Masanori Ikegami. Tuning of RF amplitude and phase for the drift tube linac in J-PARC[J]. Chinese Physics C, 2009, 33(7): 577-582. doi: 10.1088/1674-1137/33/7/014
SHEN Guo-Bao and Masanori Ikegami. Tuning of RF amplitude and phase for the drift tube linac in J-PARC[J]. Chinese Physics C, 2009, 33(7): 577-582.  doi: 10.1088/1674-1137/33/7/014 shu
Milestone
Received: 2008-09-09
Revised: 2008-10-31
Article Metric

Article Views(1423)
PDF Downloads(1675)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Tuning of RF amplitude and phase for the drift tube linac in J-PARC

    Corresponding author: SHEN Guo-Bao,

Abstract: 

The J-PARC linac has three DTL tanks to accelerate the negative hydrogen ions
from 3 MeV to 50 MeV. The RF phase and amplitude are adjusted for each
cavity with a phase scan method within the accuracy of 1° in phase and
1% in amplitude. The experimental results show a remarkable agreement
with the numerical model within a sufficient margin in the tuning of the last two DTL tanks. However, a notable discrepancy between the experiment and the numerical model is seen in the tuning of the first DTL tank. After studying with a three-dimensional multi-particle simulation, the generation of the low energy component and the pronounced filamentation are identified as the main causes of the discrepancy. The optimization of the tuning scheme is also discussed to attain the tuning goal accuracy for the first DTL tank.